Underfloor Heating Zone

A dedicated heating circuit: Type-C breaker, a heating thermostat switching both poles, and the mat itself. Heating is a fixed load, so it never shares a circuit with anything else.

Guide review
Standards context
BS 7671:2018+A4:2026 · IEC 60364

Components Needed

Live (L)Neutral (N)MCB Type-C Heating ThermostatHeating Mat

Text Wiring Path

Live → MCB C → Thermostat (L-in)
Neutral → Thermostat (N-in)
Load-L + Load-N → Heating Mat

Schematic

L N MCB C THERMOSTAT HEATING MAT
Live (line) Neutral Current flow (simulated)

Steps

  1. 1Place Live and Neutral terminals, then a Type-C MCB on the live conductor.
  2. 2Place a heating thermostat, then the heating mat as the load.
  3. 3Wire Live through the MCB into the thermostat L-in, and Neutral into its N-in.
  4. 4Take both switched poles — Load-L and Load-N — out to the mat.
  5. 5Press Run, then open the thermostat: both poles of the mat go dead, not just the live.
Key insight

A heating thermostat is double-pole: it breaks live and neutral together so the element really is isolated when it stops calling for heat. Type-C breakers ride out the element’s inrush where a Type B can nuisance-trip.

⚠ Safety practice

These walkthroughs teach wiring logic in a simulator. Real installation work must be isolated, tested dead, and carried out by a competent person — in the UK, notified under Part P or done by a registered electrician.

Terms used here

Defined in the glossary — each one opens at its own entry.

Ready to try it? This walkthrough matches a built-in guide — open it pre-built in the editor.Build this circuit →

Now wire it for real.

Build this circuit in the browser, inject a fault, and watch the protection respond.