Motion-Activated Floodlight

A PIR sensor switching a halogen floodlight. Unlike a plain switch, an active sensor needs its own live and neutral supply before it can switch anything at all.

Guide review
Standards context
BS 7671:2018+A4:2026 · IEC 60364

Components Needed

Live (L)Neutral (N)MCB PIR Motion Sensor Halogen Floodlight

Text Wiring Path

Live → MCB → PIR (L-in)
Neutral → PIR (N-in)
PIR (L-out) → Floodlight → Neutral

Schematic

L N MCB PIR SENSOR FLOODLIGHT
Live (line) Neutral Current flow (simulated)

Steps

  1. 1Place Live and Neutral, an MCB, a PIR sensor and a floodlight.
  2. 2Feed the sensor itself: Live through the MCB into L-in, Neutral into N-in.
  3. 3Take the switched L-out from the sensor to the floodlight.
  4. 4Return the floodlight's neutral directly to the supply.
  5. 5Press Run, then toggle the sensor contact to compare detected and idle states.
  6. 6Open the sensor's supply neutral in the Fault Lab — with no reference, it cannot switch.
Key insight

A passive switch intercepts one conductor; an active sensor is a small appliance with a switched output. That is why PIRs want a neutral at the switch position, and why retrofitting one into an old two-core switch drop is a wiring problem rather than a straight swap.

⚠ Safety practice

These walkthroughs teach wiring logic in a simulator. Real installation work must be isolated, tested dead, and carried out by a competent person — in the UK, notified under Part P or done by a registered electrician.

Terms used here

Defined in the glossary — each one opens at its own entry.

Ready to try it? This walkthrough matches a built-in guide — open it pre-built in the editor.Build this circuit →

Now wire it for real.

Build this circuit in the browser, inject a fault, and watch the protection respond.

Follow us on FacebookContact us